A sump pump that runs constantly is doing one of three things: keeping up with a lot of water (heavy rain, a high water table, or its own discharge soaking back to the foundation), running without moving water (a jammed float, an air lock or a blocked discharge), or short-cycling (too little float travel or a failed check valve). The pit tells you which.
Look in the pit
Which kind of constant running is it?
- Level falling or holding, water leaving outside: high inflow.
- Pit empty, pump still running: stuck float.
- Pit full, pump running, nothing leaving: air lock or blocked line.
- Pit refills right after the pump stops: check valve.
Never reach into a sump pit while the pump is plugged in.
Start here
Three different problems hide behind “it keeps running”
“Running constantly” can mean three very different things, and the fix for one can make another worse. Buying a bigger pump will not free a stuck float. Moving the discharge will not help an air lock. So before anything else, take a flashlight to the pit and answer one question: is the pump actually moving water?
- It runs and moves water. The level holds or falls and water comes out of the discharge outside. The pump is working; the question is why so much water is reaching the pit. Causes: heavy rain, a high water table, the discharge soaking back to the foundation, a hidden source, or a pump too small for the inflow.
- It runs but moves no water. The pit is empty and the motor keeps going, or the pit is full and nothing comes out outside. This is mechanical: a stuck float switch, an air lock, a check valve stuck shut, or a frozen or blocked line. It can burn out a pump, so it is the urgent one.
- It short-cycles. It turns on and off every few seconds or every minute or two, even when not much water is coming in. Causes: too little float travel, a failed check valve letting the discharge water fall back, or a basin too small for the pump.
Last reviewed: September 24, 2026
Diagnose it
What your pump's pattern tells you, and the one check for each
Find the row that matches what you see. Each check is something you can do in a few minutes with the pump plugged in and your hands out of the pit, unless the row says to unplug.
| What you see | Most likely cause | The check that separates it |
|---|---|---|
| Runs nonstop in heavy rain or snowmelt; the level is holding or dropping; water pours out the discharge outside | High inflow — the pump is doing its job | Check the level every 15 minutes. Holding or dropping is fine. Rising means the pump is losing: see what to do now, below. |
| Runs every few minutes for days or weeks without rain | High water table, discharge recycling to the foundation, a hidden water source, or check-valve drain-back | Watch where water enters the pit: from the drain tile inlet (groundwater), back down the discharge side after shutoff (check valve), or from a hose or pipe into the pit (an appliance). |
| Only runs during and right after rain, then stops within a day or two | Normal, but surface water may be reaching the drain tile fast | If it starts within minutes of rain, walk the outside in the rain: gutters, downspouts and grading. See water in the basement after rain. |
| Runs with the pit empty or nearly empty | Float switch stuck in the on position, snagged on the basin wall, cord or debris, or failed | Look at the float. Unplug from a dry spot, free it, and plug back in. If it stays on with the float down, the switch has failed. |
| Runs or hums, pit stays full, little or no water leaves outside | Air lock, check valve stuck shut or backwards, frozen or blocked discharge, a closed ball valve, or too much lift | Go outside while it runs. No flow at the outlet points to the line; a weak dribble with a gurgle points to an air lock. |
| Level jumps back up an inch or more within seconds of the pump stopping | Check valve failed, stuck open or missing | Watch one full cycle with a flashlight. See the check valve guide for how much water a bad valve returns. |
| Starts and stops every few seconds (short-cycling) | Float travel too short, float snagged mid-range, small basin, or check-valve drain-back | Measure the on and off levels with a tape. Under about 3 to 4 inches of travel in a small basin makes very short cycles. |
| Runs more every winter and spring, less by late summer | Seasonal high groundwater | Usually normal. Track it for a season; if cycles get shorter each year, have the drainage system reviewed. |
| Runs right after the washer, dehumidifier or AC drains | An appliance or condensate line draining into the pit | Follow every pipe and hose that enters the basin. Laundry water in a groundwater sump is usually not allowed; ask a plumber. |
| Starts, stops without the float moving, and the motor is hot | Thermal overload cutting out: jammed impeller, failing motor or too much lift | Unplug it from a dry spot. This is usually a pump replacement; see the replacement cost guide. |
Two patterns are easy to confuse. A pump that runs nonstop in heavy rain is often fine; a pump that runs every few minutes in a dry week is usually telling you something. And a pump that short-cycles can look like it is running constantly from upstairs, because you hear it start every minute. Standing at the pit for two or three full cycles settles which one you have.
If the pump will not start at all, or the alarm is sounding, that is a different problem; see sump pump not working and sump pump alarm going off.
Is this normal?
How often and how long a sump pump should run: the arithmetic
Nobody can give you a universal “normal” number, because a pump runs exactly as often as water arrives. But you can work out whether your pattern makes sense with three numbers: the basin diameter, how far the water drops between the float's on and off points, and how fast the pump moves water.
Gallons per cycle. Each cycle removes only the water between the on and off levels. A round 18-inch basin holds about 1.1 gallons per inch of depth and a 24-inch basin about 2 gallons per inch. With 6 inches between on and off, an 18-inch basin sends out about 6.6 gallons per cycle.
Run time. A pump that actually delivers 30 to 40 gallons a minute at your lift clears 6.6 gallons in roughly 10 to 15 seconds. That is why a healthy cycle is measured in seconds. Treat 35 gallons a minute as a rule of thumb for a common 1/3 hp pump; the real figure is on your pump's performance curve at your vertical lift.
Time between starts is simply how long it takes the incoming water to refill those 6.6 gallons. So the gap between starts tells you the inflow.
Worked example: an 18-inch basin
| Water coming in | Time between starts | Each run lasts | Starts per hour | What it usually means |
|---|---|---|---|---|
| 0.25 gal/min in | 26 min | 11 s | about 2 | Typical seepage from a damp season |
| 0.5 gal/min in | 13 min | 11 s | about 4 | Typical seepage from a damp season |
| 2 gal/min in | 3.3 min | 12 s | about 17 | Common in and after heavy rain, or with a high water table |
| 5 gal/min in | 79 s | 13 s | about 39 | Common in and after heavy rain, or with a high water table |
| 10 gal/min in | 40 s | 16 s | about 65 | Heavy inflow; fine in a storm, a warning sign if it lasts for days |
| 20 gal/min in | 20 s | 26 s | about 78 | Heavy inflow; fine in a storm, a warning sign if it lasts for days |
| 35 gal/min in | 11 s | never stops | runs nonstop | Inflow matches the pump; it runs nonstop and cannot gain |
Rule-of-thumb example: 18-inch round basin, 6 inches between on and off (≈ 6.6 gallons per cycle), pump delivering 35 gallons per minute at its lift. Run time = gallons per cycle ÷ (pump rate − inflow). Your basin, float and pump will differ.
Read the table from the top. A pump starting every 13 minutes is handling a trickle. One starting every one to three minutes is handling steady inflow of 2 to 5 gallons a minute, common during and after heavy rain with a high water table. Once inflow reaches what the pump can deliver, it never shuts off. That is the point where “running constantly” is the pump keeping pace, not the pump failing.
Measure your own inflow in two minutes
- Measure the basin's inside diameter, and mark or note the water level when the pump starts and when it stops. The difference is the float travel.
- Look up gallons per cycle below, or multiply: 18-inch basin ≈ 1.1 gallons per inch, 24-inch ≈ 2 gallons per inch.
- Time from the moment the pump stops to the moment it starts again.
- Inflow (gallons per minute) = gallons per cycle ÷ minutes between starts. For example, 6.6 gallons ÷ 1.5 minutes ≈ 4.4 gallons a minute.
- Enter that inflow in the sump pump sizing calculator to see whether your pump has enough margin at your lift.
| Basin and float travel | Gallons per cycle | Time between starts at 2 gal/min in | At 10 gal/min in |
|---|---|---|---|
| 18-inch basin, 4 in of float travel | 4.4 gal | 2.2 min | 26 s |
| 18-inch basin, 6 in of float travel | 6.6 gal | 3.3 min | 40 s |
| 18-inch basin, 10 in of float travel | 11.0 gal | 5.5 min | 66 s |
| 24-inch basin, 6 in of float travel | 11.8 gal | 5.9 min | 71 s |
| 24-inch basin, 10 in of float travel | 19.6 gal | 9.8 min | 2.0 min |
Round basins; 1 gallon = 231 cubic inches. More float travel and a wider basin mean fewer, longer cycles, which is easier on the pump.
Pattern 1
It runs because it is moving a lot of water
If the pump is moving water and the level holds or falls, the pump is not the problem; the amount of water is. These are the usual sources, roughly in order of how often they are the answer.
Heavy rain, snowmelt and a high water table
A sump collects water from the drain tile around the footing, and that drain tile sits in the ground at about the same depth as the water table. When groundwater rises, water flows into the tile and the pit continuously. The USGS notes that groundwater levels in many US aquifers follow a seasonal cycle, typically rising in winter and spring and falling in summer and fall. That is why many pumps run nearly nonstop in March and hardly at all in August.
That pressure from saturated soil is also what pushes water through basement walls and floors; see hydrostatic pressure in basements. In a house with a high water table, a pump that runs often in a wet season is keeping the basement dry, which is its job.
The discharge is recycling to the foundation
This is the cause most often missed. If the discharge pipe ends right beside the house, the water soaks into the loose backfill against the foundation, flows down to the drain tile and comes back to the pit. The pump keeps lifting the same water, often every few minutes in dry weather. Check where the pipe actually ends outside; it may have come apart, been cut short by a mower, or drain into a splash block that sends water back toward the wall.
A common target is to discharge at least 10 feet from the house onto ground that slopes away, the same distance NC State Extension gives for downspouts. Local rules on where sump water may go vary, and some municipalities do not allow it into the sanitary sewer or across a property line, so check before rerouting.
A hidden source of water
If the pit fills steadily in a dry spell and the discharge is far from the house, look for water you are adding. A leaking water service line or buried irrigation pipe can feed the drain tile all year. A simple check: with every fixture and appliance off, watch the water meter for 15 to 30 minutes. If it moves, water is going somewhere. Also check for dehumidifier, air-conditioner condensate or laundry lines draining into the pit.
The pump is undersized or worn
A pump rated at a high flow at zero lift may deliver half that when it has to push water 10 feet up and out. If the level rises during every heavy rain even though the pump never stops, it is at capacity. Pumps also lose output as impellers wear. Measure the inflow as shown above and check it against the sizing calculator; if the pump is working this hard every season, a backup pump is worth considering too (see battery vs water-powered backups).
Pattern 2
It runs but is not moving water
This is the pattern that ruins pumps. A submersible pump is cooled by the water around it and the water moving through it. Running with an empty pit or against a blocked line lets it overheat. Liberty Pumps' troubleshooting table lists the causes for a pump that runs but will not turn off, and one that runs or hums but does not pump. They map onto what you can see:
- Float switch stuck on (pit empty, pump running). The float cannot drop to the off position, usually because it is caught on the basin wall, the pump cord or the discharge pipe, or because debris has built up around it. Pumps can shift in the basin as they start. Unplug, free the float, make sure it has room to travel, and plug back in. If it stays on with the float hanging down, the switch has failed; a replacement float switch is commonly a $25–$120 part.
- Air lock (pit full, motor running, weak or no flow). Air trapped between the pump and a closed check valve stops the impeller from priming. Most manufacturers call for a small relief hole in the discharge pipe below the check valve: Zoeller specifies 3/16 inch, and Liberty recommends up to 1/8 inch in the pipe just above the pump. A small spray from that hole while the pump runs is normal. If there is no hole, or it is clogged, the pump can air-lock. Liberty's first step is to turn the pump off for several minutes, then restart.
- Check valve stuck shut or installed backwards. The arrow on the valve should point up and away from the pump. See the check valve guide.
- Frozen, crushed or clogged discharge. In winter the part of the line outside can freeze solid. See frozen sump pump discharge lines. Also check for a closed ball valve above the check valve.
- Too much lift. If the pump was replaced with a weaker one, or the discharge was rerouted higher, the pump may not have the head to push water out at all.
Pattern 3
It short-cycles: on and off every few seconds
Short-cycling means lots of starts with very little water moved each time. Motors and switches wear by the number of starts, so a pump that starts 60 times an hour ages far faster than one that runs once for a minute. The sizing calculator flags a basin that refills in under a minute at peak inflow for this reason.
- Too little float travel. Vertical floats and tethered floats can be set with only a few inches between on and off. Liberty lists “improper float switch setting” as a cause of a pump that cycles too frequently. Where the switch is adjustable, a longer range means fewer starts, but keep the on level below the drain tile inlet and follow the pump's manual.
- Check valve drain-back. Every stop sends an inch or more back into the pit. Liberty lists “check valve not installed, stuck open, or leaking” for the same symptom.
- Small basin, big pump. A high-capacity pump in a narrow pit empties it in a few seconds. Liberty's minimum basin for ordinary groundwater pumping is 14 inches in diameter and it prefers larger; installers commonly use 18 inches or more. Oversizing is not free insurance.
- A float snagged mid-range. A float that sticks partway can switch on and off on small changes in level.
Act now
What to do when your sump pump keeps running
- Check the level first. If water is rising toward the top of the basin while the pump runs, the pump is losing. Move valuables off the floor, and if the pump is failing, follow what to do when a sump pump fails.
- Go outside and look at the discharge. Flowing water means the pump is working. No water means the line is blocked, frozen, disconnected or the pump is air-locked. Water pooling at the foundation means it is recycling.
- Look at the pit through two or three cycles. Note whether the float moves freely, whether the level jumps back after the pump stops, and where water enters the basin.
- Unplug only to free a stuck float or clear an air lock, and only when the pit is low. Do it from a dry spot. Plug back in and watch a full cycle.
- Time the cycles and work out the inflow with the method above. Write it down with the date and the weather; the pattern over a few weeks is more useful than one reading.
- Run a proper test once the water is down. The bucket test confirms the float, check valve and discharge in five minutes.
Cost
What the usual fixes cost
| Fix | Part | With a plumber |
|---|---|---|
| Replace a failed float switch | $25–$120 | $100–$300 |
| Replace a failed check valve | $20–$80 | $100–$250 |
| Extend or repair the discharge line | $20–$100 | $175–$600 |
| Replace the pump in the existing pit | — | $350–$1,000 |
2026 planning ranges, not quotes. Moving a discharge underground, adding a second pump or reworking drainage costs more; see the replacement cost guide.
Most constant-running problems are fixed for the cost of a part: a float, a check valve, or a few lengths of pipe to carry the water farther away. A worn or undersized pump is a replacement, and if you are unsure how much life yours has left, see how long sump pumps last.
Rule it out
When a bigger pump is the wrong answer
- The water is recycling. A bigger pump just moves the loop faster. Extend the discharge first.
- The pump short-cycles. A bigger pump in the same small basin cycles even more. Fix the float travel or check valve, or consider a larger basin.
- The inflow is an appliance or a leak. Fix the source, not the pump.
- Surface water is reaching the drain tile within minutes of rain. Gutters, downspouts and grading are cheaper to fix than pumping capacity.
A bigger pump is the right answer when measured inflow in heavy rain is close to what the current pump delivers at its lift, and the level still rises. If the pump runs for weeks at a time even so, the drainage around the house may need a closer look; see basement drainage systems for what those involve. Any system change is worth an on-site assessment rather than a guess.
Related pages
Where to go next
Sump Pump Check Valve
How much water a failed valve sends back, and how to replace it.
Read nextSump Pump Not Working
When it will not start, hums or trips power.
Read nextSump Pump Sizing Calculator
Check your pump against your measured inflow and lift.
Read nextHydrostatic Pressure in Basements
Why a high water table keeps the pump busy.
Read nextFrozen Discharge Line
When the pump runs against ice.
Read nextSump Pump Smell
What an odor from the pit usually means.
Read nextFAQs
Sump pump running constantly: FAQs
Is it bad for a sump pump to run continuously?
During heavy rain or a spring thaw, running nonstop can be normal as long as the water level in the pit is holding or falling and water is leaving the discharge outside. It becomes a problem when it lasts for days in dry weather, when the pump runs but the level does not drop, or when the pit is empty and the pump is still running. Constant running also shortens a pump's life, so it is worth finding out why.
Is it normal for a sump pump to run every 30 seconds?
Not for long. A pump that starts every 30 seconds is either facing very heavy inflow (normal in a storm, not in a dry week) or short-cycling because the float switches over a very small range or the check valve lets the discharge water fall back into the pit. Watch the pit right after the pump stops: if the level jumps back up an inch or more within seconds, suspect the check valve.
How often should a sump pump run?
There is no single right number, because it depends on how much water reaches the pit. Many pumps sit idle for weeks in dry weather, run every few minutes to every hour in a wet season, and run every minute or two in heavy rain. What matters more is whether the pattern follows the weather. A pump that runs every few minutes after a week of dry weather is worth investigating.
How long should a sump pump run each cycle?
Usually seconds, not minutes. The pump only has to remove the water between the float's on and off levels, which in a typical 18-inch basin is about 1.1 gallons per inch, so a 6-inch range is about 6.6 gallons. A pump moving 30 to 40 gallons a minute clears that in 10 to 15 seconds. Cycles much longer than a minute mean heavy inflow, a weak or undersized pump, or a pump that is not moving water.
How long can a sump pump run continuously before burning out?
There is no fixed number. A submersible pump that is under water and actually moving water is cooled by it and is designed to run for long periods in storms. The damage comes from running dry with the pit empty (a stuck float), running against a blocked or frozen discharge, and thousands of short starts. Continuous running also uses up the pump's service life faster, so a pump that ran hard through a wet season is worth testing.
What causes a sump pump to not shut off?
If the pit is empty or low, the float switch is usually stuck in the on position, snagged on the basin wall, the power cord or debris, or has failed. If the pit is full and the pump runs without lowering it, the pump is air-locked, the check valve is stuck closed or installed backwards, the discharge is frozen or blocked, or a valve on the line is closed. If the level is dropping slowly, the pump is working but the inflow is close to its capacity.
Why is my sump pump running when it hasn't rained?
The most common reasons are a high water table (groundwater is highest in winter and spring in much of the US), the pump's own discharge soaking back down to the foundation because it empties too close to the house, a failed check valve sending water back into the pit, or a hidden source such as a leaking water line, an irrigation system, or a dehumidifier or washer draining into the pit.
Should I unplug a sump pump that keeps running?
Only briefly and only if the pit is empty or nearly empty, which suggests a stuck float. Unplug from a dry spot, never while standing in water, and plug it back in once the float is freed. Do not leave it unplugged if water is still coming in: a pit with steady inflow can overflow in minutes. If the pump is moving water, let it run and investigate why the inflow is so high.
Sources
Sources
- Liberty Pumps — Submersible Sump Pumps installation manual 7108000 (troubleshooting matrix, anti-airlock hole, basin size, check valve)
- Zoeller — sump pump installation guide (3/16-inch relief hole)
- USGS Circular 1217 — factors causing changes in ground-water levels (seasonal fluctuation)
- NC State Extension — moisture control and gutter management (discharge at least 10 feet away)
Cycle times are rule-of-thumb arithmetic for round basins; real pumps deliver less as lift increases, so check your pump's performance curve. This page is educational and does not replace an on-site inspection.